CONTROL DATA Models 9760 and 9762 Storage Module
Drives are random-access storage devices which use
removable disk packs in performing information record
and read operations. Model 9760 SMD uses the CDC®
9876 Disk Pack and has a capacity of 40 million bytes;
Model 9762 SMD uses the CDC 9877 Disk Pack, providing
an 80 million-byte capacity. Each disk pack contains five
disks, three are used in recording and two serve as
protective disks. Of the six recording surfaces provided
by the three recording disks, data is stored on five sur-
faces; the sixth is used for servo head positioning.
The basic storage module drive consists of a spindle and
associated drive motor; voice-coil head positioner and
servo system; read/write, fault, and transmitter/receiver
electronics; and an air filtration system.
Electro-mechanical options available for the 9760 and
9762 include:
• Power Supply
• Phase-locked Oscillator Data Separator
• NRZ and MFM Data Encoder
• Daisy-chaining
• Rack-mount Package
• Base Cabinet
• Data Rate of 2400 rpm, 6.45 MHz
SPECIFICATIONS
Recording Format/ Capacity —
Capacity, Unsectored: 20,160 bytes per track
100,800 bytes per cylinder
40 X 10' bytes per spindle (9760)
80 X 10' bytes per spindle (9762)
Tracks Per Surface: 404, plus 7 spares (9760)
808, plus 14 spares (9762)
Processing Speed —
Data Transfer Rate: 1 .2M bytes per second
806K bytes per second (optional)
Bite Rate: 9.67 MHz
6.45 MHz (optional)
Spindle Speed: 3600 rpm
2400 rpm (optional)
Accessing Time —
Full Stroke: 55 milliseconds (max.)
Average: 30 milliseconds
One Track: 10 milliseconds (max.)
Disk Pack —
• Type: CDC 9876 (9760)
CDC 9877 (9762)
Number of Disks: 5 (3 recording, 2 protective)
Usable Surfaces: 6 (5 read/write, 1 servo)
Diameter: 14 inches
Coating: Magnetic oxide
Recording Heads —
Type: Self-loading, single gap, no erase
Total Number: 6 (5 read/write, 1 servo)
Read/Write Width: 0.004-inch, nominal (9760)
0.002-inch, nominal (9762)
Track Spacing: 0.0052-inch, nominal (9760)
0.0026-inch, nominal (9762)
Operator Controls —
Switch/Indicators: Start/stop
Fault
Indicator Only: Ready
Interface —
Transmitters and Receivers:
Industry standard type
75110/75107, or equivalent,
are used to provide a
terminated, balanced
transmission system.
Power —
120 VAC, single phase, 60 Hz
208 VAC, single phase, 60 Hz
220 VAC, single phase, 50 Hz
Physical —
Height: lOVs inches
Depth: 30 inches
Width: 17 inches
Weight: 85 pounds
Environmental —
Operating Temperature: 60°F to 90°F
Operating Humidity: 20% to 80% R.H.
Nonoperating Temp: minus 30°F to plus 150°F
Nonoperating Humidity: 5% to 95% R.H.
Specifications are subject to change without notice.
CONTROL DATA SALES OFFICES ARE LOCATED IN PRINCIPAL CITIES THROUGHOUT THE WORLD
PERIPHERAL PRODUCTS SALES - BOX - MINNEAPOLIS, MINNESOTA 55440
TELEPHONE : (61 2) 853-3535
200.704B Litho in U.S.A. 10/73